Jan 18, 2022

थर्मल प्रतिरोध थर्मामीटर


औद्योगिक थर्मल प्रतिरोध के सामान्य दोष खुले सर्किट और औद्योगिक थर्मल प्रतिरोध के शॉर्ट सर्किट हैं। आम तौर पर ओपन सर्किट अधिक आम है, इसका कारण यह है कि थर्मल प्रतिरोध तार पतला होता है।


Thermal resistance thermometer



Open circuit and short circuit are easy to judge. You can use the "1Ω" file of the multimeter. If the measured resistance value is less than R0, there may be a short circuit; if the multimeter indicates infinity, it can be determined that the resistor body is open circuit. The short circuit of the resistor body is generally easier to handle, as long as the length and thickness of the resistance wire are not affected, find the short circuit and dry it to strengthen the insulation. To repair the open circuit of the resistor body, it is necessary to change the length of the resistance wire to affect the resistance value. For this reason, it is better to replace the new resistor body. If welding is used for repair, it must be verified after welding before use.



Dissmann fuse




प्रचुर मात्रा में फ़्यूज़, उत्पाद लाइन नई ऊर्जा वाहनों (पैक, पीडीयू, बीडीयू, इलेक्ट्रिक कंट्रोल, मोटर, एमएसडी, लो वोल्टेज वायरिंग हार्नेस), चार्जिंग सिस्टम और चार्जिंग मॉड्यूल, फोटोवोल्टिक पीवी सोलर जंक्शन बॉक्स, फोटोवोल्टिक इन्वर्टर, यूपीएस के सभी प्रासंगिक क्षेत्रों को कवर करती है। बिजली की आपूर्ति, 5 जी संचार बिजली की आपूर्ति, बीएस यूके प्लग, विद्युत घरेलू उपकरण नियंत्रण कक्ष, प्रकाश ड्राइव बिजली की आपूर्ति और इतने पर।